The Everpure H300 Drinking Water System
reduces the following contaminants:
Lead
Asbestos fibers
Cysts such as Giardia lamblia, Entamoeba histolytica
and Cryptosporidium parvum
Volatile Organic Chemicals (VOCs), including THMs And the following substances:
Chlorine taste and odor
Dirt and cloudiness*
Mold and algae*
Oxidized iron*
Oxidized manganese*
Oxidized sulfides*
Particles 1/2 micron and larger in size
The H300 delivers bacteriostatic control.**
• Replacement Filter Cartridge for H300 System. Provides bacteriostatic control.
• Reduces Volatile Organic Chemicals and 99% of lead. Exclusive precoat design reduces up to 99.99% of particles 1/2 micron and larger in size including Cyptosporidium. Reduces asbestos fibers, dirt, chloramine, chlorine taste and odor, mold and algae.
• Scale inhibitor blended into the Micro-Pure® material reduces mineral build-up in water using appliances.
• Replacing the cartridge is sanitary and as easy as changing a light bulb.
• Capacity: 300 gallons (1,135 L)
• Flow Rate: 1/2 GPM
• Certifications: NSF 42, NSF 53
• Pack Size: 1
Features
> Finely polishes treated water to premium quality for drinking and cooking.
> Reduces chlorine taste and odor and chloramines.
> Reduces dirt, rust, asbestos fibers and other particulates such as oxidized iron, manganese and sulfides.
> Reduces parasitic protozoan cysts such as Giardia, Entamoeba, Cryptosporidium.
> Controls even extreme levels of common “off” tastes and odors, including those which are earthy, moldy and fishy.
> Reduces lead to below the Federal Action Level of 10 ppb.
> Effectively reduces Volatile Organic Chemicals (VOCs), including Trihalomethanes (THMs).
> KDF Media reduces limescale build-up in water-using appliances – as tested by KDF® Fluid Treatment, Inc.
> KDF Media provides bacteriostatic control – as tested by KDF® Fluid Treatment, Inc.
Health Claim Performance Certified by NSF/ANSI*
This system has been tested according to NSF/ANSI 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving
the system, as specified in NSF/ANSI 42 and 53.
Standard 42-
Aesthetic Effects
Chlorine 2.0 mg ± 10% – >_ 50% – 96.8%
Chloramine 3.0 mg ± 10% 0.5 mg/L – – 95%
Particulate, Class I
Particles 0.5 - 1
Standard 53-Health Effects, Asbestos, Turbidity, Lead, Chloroform
(VOC surrogate chemical)
*Tested using flow rate=0.5gpm; pressure=60 psig; pH=7.5±0.5; temp.=20°C ±2.5ºC †NTU=Nephelometric Turbidity Units
|