2.5 X 40 710 Gallon per Day Thin Film Composite
The A-Series, family of proprietary thin-film reverse osmosis membrane elements are characterized by high flux and excellent sodium chloride rejection. AK Low Pressure Brackish Water Elements are selected when high rejection and low operating pressures are desired. These elements allow significant energy savings since good rejection is achieved at operating pressures as low as 100 psig (689 kPa). AK2540TF Low Pressure Brackish Water elements feature a tape outerwrap and 28 mil feed spacers. This element is designed with male end connections.
2.5 X 40 710 Gallon per Day Thin Film Composite
Operating and Design Parameters
Membrane: Thin Film Membrane (TFM )
Typical Operating Pressure: 110 psig (758 kPa)
Maximum Pressure: 400 psig (2,758 kPa)
Maximum Temperature: 122 F (50 C)
Chlorine Tolerance: 1,000 ppm-hrs, dechlorination recommended
Optimum Rejection pH: 7.0 -7.5
Operating pH Range: 4.0 - 11.0
Cleaning pH Range: 2.0 - 11.5
Maximum Pressure Drop: 10 psig (69 kPa) per element50 psig (345 kPa) per vessel
Feed NTU: <1
Feed SDI: <3
Typical Operating Flux: 10-20 GFD (15-35) L.H-1.M-2