Flow Rate GPD: 500 gpd with 99.4% rejection at 150 psi
4" diameter by 14" length
Test Conditions
The stated performance is initial (data taken after 30 minutes of operation), based on the following conditions:NaCl Solution, PPM* 1500Applied Pressure**, psig (MPa) 150 psi (1.05)Operating Temperature, F ( C) 77 (25 )Permeate Recovery 15%pH Range 6.5-7.0*ESPA4 NaCl Solution tested at 500 PPM **ESPA4 tested at 100 psigApplication Data Maximum Applied Pressure, psig (MPa) 600 (4.14)Maximum Feed Flow, GPM (m3/h) 4040-16(3.6), 8-inch-75(17.0)Maximum Operating Temperature, F ( C) 113 (45 )Feedwater pH Range* 3.0-10.0Maximum Feedwater Turbidity, NTU 1.0Maximum Feedwater SDI (15 mins) 5.0Maximum Chlorine Concentration, PPM <0.1Maximum Ratio of Concentrate to Permeate Flow for Any Element 5:1Maximum Pressure Drop for Each Element, psig 10