Operating and Design Parameters
Membrane: Thin Film Membrane (TFM )
Typical Operating Pressure: 70-300 psig (483-2,069 kPa)
Maximum Pressure: 600 psig (4,137 kPa)
Maximum Temperature: 122 F (50 C)
Chlorine Tolerance: less then 0.1 ppm
Operating pH Range: 3.0-9.0
Cleaning pH Range: 1.0-10.0
Maximum Pressure Drop: 10 psig (69 kPa) per element50 psig (345 kPa) per vessel
Feed NTU: less then 1
Feed SDI: less then 5
Typical Operating Flux: 12-20 GFD (20-35) L.H-1.M-2