Test ConditionsThe stated performance is initial (data taken after 30 minutes of operation), based on the following conditions:
NaCl Solution, PPM 1500
Applied Pressure, psig (MPa) 225 psi (1.55)
Operating Temperature, F ( C) 77 (25 )
Permeate Recovery 15%
pH Range 6.5-7.0
Application DataMaximum Applied Pressure, psig (MPa) 600 (4.14)
Maximum Feed Flow, 16 GPM (3.6 m3/h)
Maximum Operating Temperature, F ( C) 113 (45 )
Feedwater pH Range* 3.0-10.0
Maximum Feedwater Turbidity, NTU 1.0
Maximum Feedwater SDI (15 mins) 5.0
Maximum Chlorine Concentration, PPM <0.1
Maximum Ratio of Concentrate to Permeate Flow for Any Element 5:1
Maximum Pressure Drop for Each Element, psig 10 *See technical literature for extended pH tolerance
Element PerformanceElement Type: CPA2-4040
Min. Salt Rej.: 99.2%
% Nom. Salt Rej.:
99.5%@225 psi
Permeate Flow GPD (m3/d): 2,250 (8.5)