Operating and Design Parameters
Membrane: Thin Film Membrane (TFM )
Typical Operating Pressure: 100 psig (690 kPa)
Maximum Pressure: 450 psig (3,103 kPa)
Maximum Temperature: 122 F (50 C)
Chlorine Tolerance: less then 0.1 ppm
Operating pH Range: 3.0-9.0
Cleaning pH Range: 1.0-10.0
Maximum Pressure Drop: 6 psig (41 kPa) per element36 psig (248 kPa) per vessel
Feed NTU: less then 1
Feed SDI: less then 5
Typical Operating Flux: 12-20 GFD (20-35) L.H-1.M-2